Campbell CR5000 Dokumentacja Strona 171

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 238
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 170
Section 7. Measurement Instructions
7-45
Parameter
& Data Type
Enter
StartChan
Constant
The first channel that should be read on the SW8A. If the Reps parameter is
greater than 1, measurements will be made on sequential channels.
Mult, Offset
Constant,
Variable,
Array, or
Expression
A multiplier and offset by which to scale the raw results of the measurement. See the
measurement description for the units of the raw result; a multiplier of one and an
offset of 0 are necessary to output in the raw units. For example, the
TCDiff
instruction measures a thermocouple and outputs temperature in degrees C. A
multiplier of 1.8 and an offset of 32 will convert the temperature to degrees F.