SP Lite2 Silicon Pyranometer
; Set negative values to zero
2: If (X<=>F) (P89)
1: 1 X Loc [ MJ_m2 ]
2: 4 <
3: 0 F
4: 30 Then Do
3: Z=F x 10^n (P30)
1: 0 F
2: 0 n, Exponent of 10
3: 1 Z Loc [ MJ_m2 ]
4: End (P95)
5: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 1440 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
6: Real Time (P77)^23
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
7: Totalize (P72)^23429
1: 1 Reps
2: 1 Loc [ MJ_m2 ]
; -Input Locations-
; 1 MJ_m2
; * Proper entries will vary with program and input channel assignments.
; ** The 250 mV range for CR10(X) and CR500/CR510, the 200 mV range for the CR23X,
and the 500 mV range for the 21X and CR7.
; *** See Table 3 for alternative multipliers.
12