Appendix D. Examples of CAN Data Frames and Data Encoding and Decoding
32bit data frame with two 16bit unsigned integer values LSByte first.
Rxed Bit order within bytes 87654321 87654321 87654321 87654321
Rxed Byte order Byte 1 Byte 2 Byte 3 Byte 4
Values B A
Bit order within values 8 1 16 9 8 1 16 9
Value byte order LSByte MSByte LSByte MSByte
Start bit (parameter 09:) RH ref 32 25 24 17 16 9 8 1
Start bit (parameter 09:) LH ref 1 8 9 16 17 24 25 32
Start bit (parameter 09:) Right Hand reference.
1: SDM-CAN (P118)
1: 0 SDM Address
2: 1 Time-quanta
3: 5 Tseg1
4: 2 Tseg2
5: 1000 ID Bits 0..10
6: 0000 ID Bits 11..23
7: 00 ID Bits 24..28
8: 2 Rx, unsigned int, LSB 1st
9: 9 Start Bit No.
10: 16 No. of Bits
11: 2 No. of Values
12: 1 Loc [ value_A ]
13: 1.0 Mult
14: 0.0 Offset
Start bit (parameter 09:) Left Hand reference.
2: SDM-CAN (P118)
1: 00 SDM Address
2: 1 Time-quanta
3: 5 Tseg1
4: 4 Tseg2
5: 1001 ID Bits 0..10
6: 0000 ID Bits 11..23
7: 00 ID Bits 24..28
8: 2 Rx, unsigned int, LSB 1st
9: 24 -- Start Bit No.
10: 16 No. of Bits
11: 2 No. of Values
12: 1 Loc [ value_A ]
13: 1.0 Mult
14: 0.0 Offset
D-3