Number 4250-2010
Revision 0.1
Date MAY 1996
Page 21 of 37
EXECUTE Execute the Handar DCP communications program "TERM" from
PROGRAM the PC computer.
When the "TERM" setup screen (see Figure 4-4) is displayed on the
computer screen, press F2 to switch to the correct baud rate (300
baud).
Connect the serial port of the PC computer to the DCP
programming port (see Figure 4-2 for location) using the DCP
programming cable. After the connection is complete, the "TERM"
programming screen of Figure 4-6 should be displayed on the
computer screen.
Initiate the program download by pressing the F6 key.
The next screen prompt displayed is "LOAD PS PROG->DCP."
Press ENTER in response to this prompt.
The screen prompt "ENTER NAME OF PROGRAM FILE:" is then
displayed. Enter 540ROT.DCP to program a Handar 540 DCP. To
program a Handar 570A DCP, enter 570ROT.DCP.
While the program is loading, the message "P LOADING
PROGRAM" will be displayed. Upon completion of the download,
the message "P DONE" will be displayed. The "P" at the beginning
of a display message indicates that the DCP is in the "PROGRAM"
mode. An "R" at the beginning of a message indicates that the DCP
is in the "RUN" mode.
EDIT Procedures for editing the site-specific parameters are as follows:
PARAMETERS
Editing commands (the boldfaced character) used in these
procedures are as follows:
I Station ID
J DCP time
S Time remaining before next scan
T Time remaining before next transmission
M Data channel select
N Define Sensor Type
K Program GOES/Radio
V Scroll Down
U Scroll Up