CSIOPCServer
User’s Manual and
Installation Guide
Revision: 10/09
Copyright © 2001-2009
Campbell Scientific, Inc.
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - Installation Guide

CSIOPCServerUser’s Manual andInstallation GuideRevision: 10/09Copyright © 2001-2009Campbell Scientific, Inc.

Strona 2

CSIOPCServer Note that data must be collected from a datalogger and stored in the LoggerNet data cache before that data will be available to OPC clien

Strona 3 - License for Use

CSIOPCServer The format may vary somewhat from the examples given above, depending upon the client. NOTE 4.2 CSIOPCServer Browser The CSIOPCServer al

Strona 4 - Limited Warranty

CSIOPCServer • The specified data tag does not exist in the datalogger table (because an error was typed when entering the data tag directly, a new p

Strona 5

CSIOPCServer Each device in the network map is represented by two tables in the statistics device. The names of these tables are the result of appendi

Strona 6

CSIOPCServer 6.3.2.1 Communication Enabled Type: boolean Applies to: all device types Description: Relates whether communication is enabled for th

Strona 7

CSIOPCServer Description: Describes the current communication state of the device. The following values are defined: 1. normal (last communication s

Strona 8 - Application

CSIOPCServer 6.3.2.11 Last Data Coll Type: stamp Applies to: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T, CR10X-TD, CR510T, CR23X-TD, CR9000

Strona 9 - Telecommunications

CSIOPCServer 5. comm disabled - Communications for this device, one of its parents, or for the whole network is disabled. 6. invalid table defs - Co

Strona 10 - 4. Identifying Data Values

CSIOPCServer 6.3.2.19 Line State Type: enumeration Applies to: All devices except BMP5 (PakBus) dataloggers Description: The current line state fo

Strona 11 - 5. Data Reliability

CSIOPCServer Description: Reflects the total number of final storage values that need to be collected from final storage area one of a classic datalo

Strona 13

CSIOPCServer 6.3.2.27 Prog Overrun Type: uint4 Applies to: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X Description: Relates the number of datalogg

Strona 14

CSIOPCServer 6.3.2.32 Lith Batt Volt Type: float Applies to: CR10X, CR500, CR510, CR23X Description: Reports the lithium battery voltage on classi

Strona 15

CSIOPCServer 16 6.3.3.2 Avail Virt Mem Type: uint4 Description: Relates the amount of virtual memory that is available to the server process. 6.3.3

Strona 17

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strona 18

License for Use This software is protected by United States copyright law and international copyright treaty provisions. The installation and use of t

Strona 19

Limited Warranty The following warranties are in effect for ninety (90) days from the date of shipment of the original purchase. These warranties are

Strona 20

CSIOPCServer Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks

Strona 22

CSIOPCServer 1. What is OPC and CSIOPCServer? OPC is an acronym for "OLE (Object Linking and Embedding) for Process Control". It is a set o

Strona 23

CSIOPCServer Because the CSIOPCServer registration information is written to the Windows registry, if the executable is moved to another directory the

Strona 24

CSIOPCServer The diagram below depicts the flow of information between the datalogger network, LoggerNet communications server, LoggerNet client appli