D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 1 - 3-D sonic anemometer Standard Operating Procedure (SOP) for the Baltimore PM Supersite Janu
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 2 - Measurement of wind speed and air temperature and computation of sensible heat and momentum flu
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 3 - The sonic transducers are sealed and will not be damaged should they become wet. The wind measu
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 4 - 4. Installation 4.1 Orientation The three wind components are defined by a right handed ortho
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 5 - Battery Terminal Description Color Positive 12 VDC Red Negative Ground Black Table 1. CSAT3 P
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 6 - CSAT3 will send wind speed and the sonic virtual temperature via the SDM bus to the datalogger.
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 7 - 10. Daily Checks Check if current time is displayed on CR23X. This means that data logger has
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 8 - Appendix 1. Sample Program for SDM-CSAT3 (P107) used with CR23X ;{CR23X};*Table 1 Program01: 0.
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 9 - 12: If Flag/Port (P91)1: 10 Do if Output Flag is High (Flag 0)2: 10 Set Output Flag High (Flag