Campbell CS655 Instrukcja Użytkownika Strona 15

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 34
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 14
Model HFP01SC Self-Calibrating Soil Heat Flux Plate
6.3.2 Example 2. Sample CR10(X) Program Using a Single-Ended
Measurement Instruction
TABLE 6-4 provides the wiring for Example 2.
TABLE 6-4. Wiring for Example 2
Description Color CR10(X)
Sensor Signal White 1H
Sensor Signal Reference Green AG
Shield Clear G
Heater Resistor Signal Yellow 1L
Heater Resistor Signal Reference Purple AG
Shield Clear G
Power Red SW12
Power Reference Black G
External Power Control jumper wire SW12-CTRL to C8
;{CR10X}
;
*Table 1 Program
01: 1 Execution Interval (seconds)
;Measure HFP01SC on smaller range.
;
1: Volt (SE) (P1)
1: 1 Reps
2: 22 7.5 mV 60 Hz Rejection Range
3: 1 SE Channel
4: 2 Loc [ shf_mV ]
5: 1 Mult
6: 0 Offset
;Measure HFP01SC on larger range.
;
2: Volt (SE) (P1)
1: 1 Reps
2: 23 25 mV 60 Hz Rejection Range
3: 1 SE Channel
4: 8 Loc [ shf_mV_a ]
5: 1 Mult
6: 0 Offset
9
Przeglądanie stron 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 33 34

Komentarze do niniejszej Instrukcji

Brak uwag