Appendix D. RAWS-7 Data Format
D-7
16: End (P95)
; Correct Fuel Moisture
17: Polynomial (P55)
1: 1 Reps
2: 28 X Loc [ FuelM ]
3: 28 F(X) Loc [ FuelM ]
4: -220.14 C0
5: 365.89 C1
6: -114.96 C2
7: 0.0 C3
8: 0.0 C4
9: 0.0 C5
; Convert Air Temp to degrees F
18: Z=X*F (P37)
1: 3 X Loc [ AirTemp ]
2: 1.8 F
3: 3 Z Loc [ AirTemp ]
19: Z=X+F (P34)
1: 3 X Loc [ AirTemp ]
2: 32.0 F
3: 3 Z Loc [ AirTemp ]
; Eliminate RH values greater than 100
20: If (X<=>F) (P89)
1: 4 X Loc [ RH ]
2: 3 >=
3: 100 F
4: 30 Then Do
21: Z=F (P30)
1: 100 F
2: 0 Exponent of 10
3: 4 Z Loc [ RH ]
22: End (P95)
; correct zero wind speed offset.
23: If (X<=>F) (P89)
1: 5 X Loc [ Wspd ]
2: 4 <
3: 0.4001 F
4: 30 Then Do
24: Z=F (P30)
1: 0 F
2: 0 Exponent of 10
3: 5 Z Loc [ Wspd ]
25: End (P95)