G.1.9 50 Hz Measurement Example — One CDM-VW305, Eight
Channels, Rainflow Histogram
'===RFH-50HzExample8Ch_4-25-13.CR3===
'CR3000 datalogger
'CDM-VW305 vibrating-wire analyzer
'Program to read 50-Hz dynamic data from one CDM-VW305 analyzer measuring eight channels.
'Demonstrate use of rainflow histogram.
'IMPORTANT -- Ensure that the CPI address coded on the following line matches the address
'reported for the attached analyzer in the DevConfig or DVWTool software.
Const CPI_ADDR = 1 '<<<<<<<<<<<<<<SET CPI ADDRESS HERE
Public Freq(8)
Public Diag(8) As Long
Public StaticFreq(8)
Public Therm(8)
Public DynStdDev(8)
'Rainflow : Mean Bins and Amplitude Bins dimensions
Const MBINS = 10
Const ABINS = 10
'Rainflow-Histogram Outputs - 2 dimensional arrays
Public RF1(MBINS,ABINS)
Public RF2(MBINS,ABINS)
Public RF3(MBINS,ABINS)
Public RF4(MBINS,ABINS)
Public RF5(MBINS,ABINS)
Public RF6(MBINS,ABINS)
Public RF7(MBINS,ABINS)
Public RF8(MBINS,ABINS)
Dim Enable(8) As Long = { 1, 1, 1, 1, 1, 1, 1, 1}
Dim Max_AMP(8) = { 0.002, 0.002, 0.002, 0.002, 0.002, 0.002, 0.002, 0.002}
Dim F_Low(8) = { 300, 300, 300, 300, 300, 300, 300, 300}
Dim F_High(8) = { 6000, 6000, 6000, 6000, 6000, 6000, 6000, 6000}
Dim OutForm(8) As Long = { 0, 0, 0, 0, 0, 0, 0, 0}
Dim Mult(8) = { 1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 1.0}
Dim Off(8) = { 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0}
Dim SteinA(8) = { 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0}
Dim SteinB(8) = { 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0}
Dim SteinC(8) = { 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0}
'Rainflow-Histogram configuration
Dim RF_mean_bins(8) As Long = { MBINS, MBINS, MBINS, MBINS, MBINS, MBINS, MBINS, MBINS} 'Mean
Bins
Dim RF_amp_bins(8) As Long = { ABINS, ABINS, ABINS, ABINS, ABINS, ABINS, ABINS, ABINS}
'Amplitude
'Bins
Dim RF_Lo_lim(8) = { 400.0, 400.0, 400.0, 400.0, 400.0, 400.0, 400.0, 400.0} 'Low
Limit
Dim RF_Hi_lim(8) = {4000.0,4000.0,4000.0,4000.0,4000.0,4000.0,4000.0,4000.0} 'High
'Limit
Dim RF_Hyst(8) = { 0.005, 0.005, 0.005, 0.005, 0.005, 0.005, 0.005, 0.005}
'Hysteresis
'Output format consists of three digits ABC, that can be either 1 or 0
Dim RF_OutForm(8) As Long = { 110, 110, 110, 110, 110, 110, 110, 110}
'RF Histogram Digit Code Histogram output result
'----------------------- ------------------------
'A = 0 Reset histogram after each output.
'A = 1 Do not reset histogram.
'B = 0 Divide bins by total count.
'B = 1 Output total in each bin.
'C = 0 Open form. Include outside range values in end bins.
'C = 1 Closed form. Exclude values outside range.
CDM_VW300Config(1,CPI_ADDR,0,Enable(),Max_AMP(),F_Low(),F_High(), _
OutForm(),Mult(),Off(), SteinA(),SteinB(),SteinC(), _
RF_mean_bins(),RF_amp_bins(),RF_Lo_lim(), _
RF_Hi_lim(),RF_Hyst(),RF_OutForm())
DataTable (static,true,-1)
Sample (8,StaticFreq(),IEEE4)
Sample (8,Therm(),IEEE4)
Sample (8,DynStdDev(),IEEE4)
EndTable