Strona 1 - Pressure Sensor

CS100 Barometric Pressure Sensor Instruction Manual Issued 16.9.08 Copyright © 2002-2008 Campbell

Strona 2

CS100 Barometric Pressure Sensor 2 2. Specifications 2.1 Performance 2.1.1 Performance for “Standard” Range Option Measurement Range: 600 mb to 11

Strona 3 - Guarantee

Instruction Manual 3 Current Consumption: 3 mA nominal (operating mode) 1 µA quiescent (sleep mode) Signal Output 0 to 2.5 Vdc Warm-up Time: <

Strona 4

CS100 Barometric Pressure Sensor 4 4. Wiring 4.1 Datalogger Connection Before connecting the barometer to the datalogger, a yellow warning label mus

Strona 5 - PLEASE READ FIRST

Instruction Manual 5 4.2 5-pin Screw Terminal Plug Connector The datalogger connects to the CS100 via a 5-pin screw terminal plug connector. This co

Strona 6

CS100 Barometric Pressure Sensor 6 In Program Example 2, the CR10X datalogger (Edlog datalogger) turns on the CS100 one minute before the top of the h

Strona 7 - Contents

Instruction Manual 7 5.3 Program Examples The CS100 wiring instructions for the example programs are shown in Table 4 below. Table 4. Wiring for Ex

Strona 8

CS100 Barometric Pressure Sensor 8 Example 2. Sample Program for CR10X (Edlog) Datalogger ;{CR10X} ; *Table 1 Program 01: 1 Execution Interval (se

Strona 9 - 1. Introduction

Instruction Manual 9 *Table 3 Subroutines End Program -Input Locations- 1 P_mb * Proper entries will vary with program and datalogger channe

Strona 10 - 2. Specifications

CS100 Barometric Pressure Sensor 10 EmEftft m()().=3 281 (2) The corrections involved can be significant: e.g. at 1000mb and 20°C, barometric pressure

Strona 13 - 5. Programming

CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci

Strona 14 - Options

Guarantee This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for twelve months from date of delivery.

Strona 16

PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North American

Strona 18

i Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to spe

Strona 20

1 CS100 Barometric Pressure Sensor 1. Introduction The CS100 is a capacitive pressure transducer that uses the Setra's electrical capacitor tech