Met One 034B Wind Set
7.2 Mounting Options
The 034B can be attached to a CM200-series crossarm via a 17953 NU-RAIL
fitting or a CM220, Right Angle Mounting Bracket. Procedure for using these
mounts is provided in the Quickstart (Section 4.1, Step 1Mount the Sensor).
Alternatively, the 034B can be attached to the top of a CM106B, CM110,
CM115, or CM120 tripod via the CM216, Sensor Mounting Kit. The CM216
extends 10 cm (4 in) above the mast of the tripod.
FIGURE 7-1. CM216 mount
7.3 Wiring
Connections to Campbell Scientific CRBasic dataloggers are given in TABLE
7-1. To wire an Edlog datalogger, see an older manual at
www.campbellsci.com/old-manuals, or contact a Campbell Scientific
application engineer for assistance.
TABLE 7-1. Connections to Campbell Scientific Dataloggers
Color
Wire Label
CR6
CR9000X
CR800
CR5000
CR3000
CR1000
CR200(X)
Red
WS Signal
Pulse
P_SW
Black
WS Signal Ref
Green
WD Signal
SE Analog
SE Analog
Blue
WD Volt Excite
Excitation (VX or EX)
Excitation (VX or EX)
White
WD Signal Ref
Clear
Shield