Campbell COM220 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Networking Campbell COM220. Campbell COM220 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - COM220 Telephone Modem

COM220 Telephone ModemRevision: 8/11Copyright © 1997-2011Campbell Scientific, Inc.

Strona 2 - Warranty and Assistance

COM220 Telephone Modem 3.3 Telephone to MD485 or Telephone to RF Systems Telephone to MD485 or telephone to radio configurations can be utilized for

Strona 3 - Table of Contents

COM220 Telephone Modem Phone wires are live, typically with low voltage (24 Vdc). While not harmful in most situations, Campbell Scientific recommen

Strona 4 - List of Tables

COM220 Telephone Modem FIGURE 6. Side View of Surge Suppressor Wiring 4. Modem Settings The COM220 is shipped from the factory with default setting

Strona 5

COM220 Telephone Modem Some of the AT command settings one may change are: Disable auto-answer: This option is used only when the modem is not to ans

Strona 6 - 1.2 Computer Requirements

COM220 Telephone Modem 4) If the COM220 is set for Modem Enable (DIP switch 1 open), verify that the ME baud rate selected (switches 3, 4) agrees wit

Strona 7 - 3. Installation

COM220 Telephone Modem 11) Can you attach a normal analog telephone to the line and make a call out? If not, contact your local telephone company.

Strona 8 - WIRING PANEL

COM220 Telephone Modem 12

Strona 9 - SCIENTIFIC

Appendix A. Changing COM220 Settings Changing any of the modem's settings may result in communication problems. After changing the settings, t

Strona 10 - 3.4 Telephone Service

Appendix A. Changing COM220 Settings TABLE A-1. Selecting ME Baud-rates via DIP Switches 3 and 4 ME Baud-rate Switch 3 Switch 4 9600 Open Open 38

Strona 11

Appendix A. Changing COM220 Settings FIGURE A-1. COM220 to Computer Connection To configure the COM220 with Hayes AT commands, follow these steps:

Strona 12 - 4. Modem Settings

Warranty and Assistance PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from def

Strona 13 - 5. Troubleshooting

Appendix A. Changing COM220 Settings 7) Follow the instructions that appear in the terminal emulator screen (Figure A-3). 8) Be sure to save all n

Strona 14

Appendix A. Changing COM220 Settings FIGURE A-3. Terminal Emulator Screen in Device Configuration HAYES AT COMMAND SUMMARY: This manual does not at

Strona 15

Appendix A. Changing COM220 Settings M0 Speaker always off M1 (default) Speaker on during call establishment M2 Speak on during entire call sessio

Strona 16

Appendix A. Changing COM220 Settings FIGURE A-4. Send OS Screen in Device Configuration A.4 Program Examples A.4.1 ModemCallback Example (for CR1

Strona 17 - Settings

Appendix A. Changing COM220 Settings ModemCallBack(Result,ComSDC7,9600,0,"5551212","",40,60,Abort) CallTable Test5 NextScan

Strona 18 - A.2 Hayes AT Commands

Appendix A. Changing COM220 Settings The COM220 can return several possible responses once connected (each terminating in a carriage return): CAUTION

Strona 19

Appendix A. Changing COM220 Settings Do not put Instruction 97 inside a loop or conditional statement; it must be executed each time the table is run

Strona 20

Appendix A. Changing COM220 Settings 12: Initiate Telecommunications (P97) 1: 22 Phone Modem/9600 Baud ;set baud-rate/modem 2: 5 Disable

Strona 21

Appendix A. Changing COM220 Settings A-12 SequentialMode DataTable (TestA,1,-1) DataInterval (0,2,Sec,10) Minimum (1,BatteryVoltage,FP2,0,False) S

Strona 22

Appendix B. CS I/O Connection B.1 CS I/O 9-Pin Connection The pin out of the connector is shown in Figure B-1. The direction of the signal relative

Strona 23 - A.4 Program Examples

COM220 Telephone Modem Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat®

Strona 24

This is a blank page.

Strona 25

Appendix C. Theory of Operation C.1 Theory of Operation The COM220 modem is used to transmit data over bandwidth-limited channels such as telephone

Strona 26

This is a blank page.

Strona 27 - Datalogger Router

Appendix D. FCC Warning to Users of Class B Computing Devices This equipment generates, uses, and can radiate radio frequency energy, and if not ins

Strona 28

This is a blank page.

Strona 29 - B.1 CS I/O 9-Pin Connection

Appendix E. IC Information Industry Canada (IC) was formerly known as DOC. NOTE CP-01, Issue 8, Part I Section 14.1 “NOTICE: The Industry Canada la

Strona 32

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strona 33 - Class B Computing Devices

COM220 Telephone Modem Table of Contents ii D. FCC Warning to Users of Class A Computing Devices...D-1 E. IC Information

Strona 34

COM220 Telephone Modem 1. Introduction 1.1 General Description The COM220 modem is a selectable-baud-rate modem employing the Hayes AT command set.

Strona 35 - Appendix E. IC Information

COM220 Telephone Modem The COM220 is connected to a CSI datalogger by a 9-pin subminiature D cable. This is the same 9-pin CS I/O interface common to

Strona 36

COM220 Telephone Modem 2. Specifications • Standards: V.92, K56Flex, V.90, V.34, V.32bis, V32, V23, V22bis, V22, V.21, B212, B103 • Registration:

Strona 37

COM220 Telephone Modem TABLE 1. Dataloggers that Require Direct 12 VDC Connection to COM220 CR10(X) with silver wiring panel CR10(X) with black CR10

Strona 38

COM220 Telephone Modem CAMPBELLSCIENTIFICINC.CR10MADE IN USAWIRING PANEL NO.EARTHDIFFSEAG H L AG H L AG H L AG GGE3 AG4 5 678 910 1112GGGG12V 12VSWITC