CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) Issued: 17.6.14 Copyright © 2013-14 Campbell Scientific
1 CS-GSM/GPRS digital transceiver kits This manual provides the details of how to use the CS-GSM/GPRS digital transceiver kits with Campbell Scientifi
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 2 protocol is supported either using the built-in TCP/IP capability of some Campbel
Using with Campbell Scientific Dataloggers 3 4. Connect the power supply to the COM110A modem, by connecting the red/black power lead either directly
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 4 4. Connect the modem to the PC using the programming cable (use a serial to US
Using with Campbell Scientific Dataloggers 5 for a direct connection to the serial port, CS I/O ME for the SC-WMI or one of the SDC options to match t
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 6 9. Turn on the power to the datalogger and COM110A modem. The status LED on the
Using with Campbell Scientific Dataloggers 7 mode (see Appendix D for more information). Your airtime provider will normally supply you with an extra
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 8 If you cannot use a base station GSM modem, lower cost calls may also be possible
Using with Campbell Scientific Dataloggers 9 Can synchronise the datalogger clock to Internet time (networktimeprotocol). Can send data to other
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 10 searching for “Fixed IP SIM” on the internet making sure the offering is not a 3
Using with Campbell Scientific Dataloggers 11 dynamic name service in this instance (please contact Campbell Scientific for more details). More common
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 12 significantly – the transmitter using an extra 100-400 mA depending on the insta
Using with Campbell Scientific Dataloggers 13 5.6 Sending configuration commands to the modem It is often advisable to reset the modem at regular i
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 14 The SC-WMI is not recommended for use where other devices are sharing the CS I/O
Using with Campbell Scientific Dataloggers 15 The cable required for the direct connection to a datalogger serial port is supplied as part of the CS-G
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 16 6.4 Selecting and Connecting an Antenna When selecting an antenna, please note
Using with Campbell Scientific Dataloggers 17 6.4.1 Antenna Supplied by Campbell Scientific Campbell Scientific can supply various antennas, if requi
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 18 Higher gain YAGI style antennas are available from Campbell Scientific to specia
Using with Campbell Scientific Dataloggers 19 This program is provided free of charge but is only licensed for use with COM110A modems purchased from
Guarantee This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for twelve months from date of delivery.
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 20 Setup – Settings - Datalogger port: allows you to select the serial port on the
Using with Campbell Scientific Dataloggers 21 less frequent than the default time of 60 mins then increase this time – at the possible cost of the ext
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 22 When this window is opened on the home screen an additional entry window app
Using with Campbell Scientific Dataloggers 23 8.1 Configuring a Desk-Top Modem as a Base Station You can use most desktop landline and even cellphone
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 24 To add this setting, use the Phone modem option in Loggernet where you can edit
Using with Campbell Scientific Dataloggers 25 Where the number of outgoing IP ports is limited, perhaps due to a firewall restriction, Pakbus loggers
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 26 9.2 Setting up call-back in Loggernet Where the logger is programmed to call
Using with Campbell Scientific Dataloggers 27 9.2.2 Setting up call-back in Loggernet Version 4 In Loggernet 4 there is a new root device called a Pa
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 28 You then need to attach a datalogger entry to the PakbusTCPServer for each data
Using with Campbell Scientific Dataloggers 29 minutes or set up another process, e.g. low frequency pinging, to prevent the datalogger resetting the c
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 30 network. Generally, this will provide a reliable connection long term. However,
Using with Campbell Scientific Dataloggers 31 If the COM110A modem has definitely been registered on the GSM network, check that the registration is f
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 32 If you manually dial the number with a phone and hear a buzzing noise rather
Using with Campbell Scientific Dataloggers 33 Check the modem was configured correctly. Check you have set the correct APN, username and passwor
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 34 Messages that can appear include: Message Cause/Fault ppp initialized PPP was en
Using with Campbell Scientific Dataloggers 35 Make sure any local firewalls allow you to make outgoing connections on the ports being used. (Some i
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) 36 the logger settings first) Click on connect. This opens a dumb terminal emulato
A-1 Appendix A. Using the COM110A with the PIN Security Feature Enabled It is possible to use the COM110A with Campbell Scientific dataloggers with th
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) A-2 'Main Program BeginProg 'Normal measurements in the main scan here
Appendix A. Using the COM110A with the PIN Security Feature Enabled A-3 A3. CR10X Program Example Using Instruction P97 with the generic modem opti
PLEASE READ FIRST About this manual Some useful conversion factors: Area: 1 in2 (square inch) = 645 mm2 Length: 1 in. (inch) = 25.4 mm
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) A-4 2: 1 Disabled when User Flag 1 is High 3: 20 Seconds Call Time L
Appendix A. Using the COM110A with the PIN Security Feature Enabled A-5 2: 30 Then Do 12: If Flag/Port (P91) 1: 12 Do if Flag 2 is Hi
B-1 Appendix B. Controlling the Power Supply to the COM110A Modem This Appendix describes how the datalogger can be used to control the power supply
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) B-2 B1.1 CRBasic Program Example of Power Control This example can be used on the
Appendix B. Controlling the COM110A Power Supply B-3 'First send the +++ sequence to get the modem in command mode - in case online
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) B-4 B.1.2 CR10X Program Example ;COM110A power control example code for the CR10X
Appendix B. Controlling the COM110A Power Supply B-5 CAUTION If power is limited and the turn-on time has to be kept very short, it is
C-1 Appendix C. Useful Configuration Commands for the COM110A This section gives details of some of the useful test commands that can be used during
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) C-2 C.2 Network Registration Checks AT+COPS Operator selection Test command AT+CO
Appendix C. Useful Configuration Commands C-3 AT+CREG Network registration Test command AT+CREG=? Response +CREG: list of supported <n>s OK Par
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) C-4 C.3 PIN Configuration AT+CPIN Enter PIN Test command AT+CPIN=? Response OK Re
Appendix C. Useful Configuration Commands C-5 To switch between EU/US band(s) for the COM110A, use a communication software such as a HyperTerminal,
D-1 Appendix D. Using the COM110A in Transparent Mode for GSM Dial-up use It is possible to use the COM110A in transparent mode, when the default non-
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) D-2
E-1 Appendix E. Resetting the COM110A Module under Program Control This Appendix describes how the datalogger can be used to send commands to the COM
CS-GSM Digital Transceiver Kits (including the COM110A modem) E-2 SlowSequence 'Run once a minute so can have one minute resolution of timin
Appendix E. Resetting the COM110A Under Program Control E-3 ; is loaded to as flag 8 will be low then. 1: If time is (P92) 1: 1439 Minutes (Se
i Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to spe
F-1 Appendix F. Configuring the COM110A via the datalogger It is possible to reconfigure a GSM modem connected to a logger without the programming ca
CS-GSM/GPRS Digital Transceiver Kits (including the COM110A modem) F-2 11. The logger should then report “opening 2” (in the case of ComME), which m
CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbel
ii 9. Using Loggernet for GPRS communications ... 24 9.1 Setting up to call a logger with a fixed IP address ...
iii E. Resetting the COM110A Module under Program Control ................ E-1 E.1 Princip
Komentarze do niniejszej Instrukcji