7
HUB-SDM5 5-Channel Hub for SDM Peripherals
e HUB-SDM5 can make it more convenient to con-
nect multiple SDMs to a single datalogger. It con-
sists of DIN-rail mounted busbars housed in a small
environmental enclosure. Connection terminals for
up to ve external SDM devices are included. e
HUB-SDM5’s enclosure is tted with six compression
ttings on its lower surface. Each compression tting
accommodates entry/exit of one cable. e enclosure
also has an external bracket for attaching the enclosure
to a pole or mast.
Spring-loaded guillotine terminals mounted on a DIN-
rail provide connection points for individual wires. e
terminals are grouped in ve sets of six terminals each
allowing connection of ve groups of ve incoming
wires and one common outgoing wire. A small screw-
driver is included to open the guillotines for wire entry.
HUB-SDM8 8-Channel Hub for SDM Peripherals & Power Connectors
e HUB-SDM8 is intended for customers who want
to connect multiple SDMs to the same datalogger, as
well as run multiple power connections using a 16 AWG
wire. e HUB-SDM8 is comprised of an environmen-
tal enclosure with eight compression ttings (two larger)
and eight terminal strips. Up to ve external SDMs
can be connected to the HUB-SDM8’s terminals.
Spring-loaded guillotine terminals mounted on a DIN-
rail provide connection points for individual wires. A
small screwdriver is included to open the guillotines
for wire entry.
CABLE5CBL-L 5-Conductor 24-AWG Cable with Drain Wire
e CABLE5CBL-L is recommended for connecting
the SDM to the datalogger. A 1- cable length should
be su cient when both the datalogger and SDM are
housed within an ENC12/14 enclosure; a 2- length
may be required if the datalogger and the SDM are
housed at opposite ends of an ENC16/18 enclosure.
Cable lengths should be kept as short as possible.
Long cable lengths can adversely a ect the measure-
ment. e SDMSpeed CRBasic instruction should be
used if the cable length is longer than 20 .