Campbell Met One 034A-L Instrukcja Operatora Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 75
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
12
Installation, Operation and Maintainance of Automatic Meteorological Stations
Introduction
Figure 1: Met Station
The main components of the Met Station are:
• Tripod(partlymanufacturedlocally)
• ProtectiveenclosureENC12/14
• CR10Xstorageandcontrolmodule(insidetheprotectiveenclosure)
• PS12LApowersupply(includingrechargeablebattery;insidetheprotectiveenclosure)
• MSX10RSolarpanel
• Sensors
• SM4Mstoragemodule(asingleunitusedformultiplestations)
• CR10KDkeyboarddisplay(asingleunitusedformultiplestations)
Figure 2 displays the CR10X storage and control module, which is the actual data logger. The various sensors will
be connected to the green terminal strip, following a wiring schedule presented later in this manual.
Lighting Rod
Pyranometer
Wind Vane
Anemometer
Solar Panel
Temperature & RH
Sensor
Protective
Enclosure (Having
D. Logger & Power
Supply)
Lighting Rod