60
Installation, Operation and Maintainance of Automatic Meteorological Stations
Annex 4: Input Storage Locations Used by METSTAT
See METSTAT Structure Diagram presented in Annex 3.1 for the use of the various variables. Use “*6” Mode and
press “A” equivalent to “enter” to proceed from one variable to another.
Address
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
METSTAT Code
[AIR_TEMP]
[RH]
[SOLAR_RAD]
[WIND_SPD]
[WIND_DIR]
[RAIN]
[SVP]
[VP]
[AUX_SVP]
[VPD]
[FM_SOLAR]
[OH_SOLAR]
[AUX_OHS]
[AUXFM_SO]
[OD_SOLAR]
[AUX_ODS]
[OH_AIRT]
[OH_VP]
[[OH_VPD]
[OH_WINDS]
[FM_RAIN]
[SIGN1440]
[BATT_VOLT]
[LOGGER_ID]
Description
Air Temperature
Relative Humidity
Solar Radiation
Wind Speed
Wind Direction
Rainfall
Saturated Vapor Pressure
Vapor Pressure
Auxiliary Value
Vapor Pressure Deficit
Cumulative 5 Minutes Solar Radiation
Cumulative 1 Hour Solar Radiation
Auxiliary Value
Auxiliary Value
Cumulative 1 Day Solar Radiation
Auxiliary Value
Average 1 Hour Air Temperature
Average 1 Hour Vapor Pressure
Average 1 Hour Vapor Pressure Deficit
Average 1 Hour Wind Speed
Cumulative 5 Minutes Rainfall
METSTAT Program Signature
Battery Voltage
Datalogger ID
Unit
[ºC]
[%]
[W/M2]
[M/S]
[degrees]
[MM]
[kPa]
[kPa]
na
[kPa]
[J/M2]
[KJ/M2]
na
na
[MJ/M2]
na
[ºC]
[kPa]
[kPa]
[M/S]
[MM]
na
[V]
na
Annex 4: Input Storage Locations Used by METSTAT
Annexes
Komentarze do niniejszej Instrukcji