Manual
1: 1 Reps
2: 24 Loc [ LOGGER_ID ]
49: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
50: Average (P71)
1: 1 Reps
2: 17 Loc [ OH_AIRT ]
51: Average (P71)
1: 1 Reps
2: 18 Loc [ OH_VP ]
52: Average (P71)
1: 1 Reps
2: 19 Loc [ OH_VPD ]
53: Sample (P70)
1: 1 Reps
2: 12 Loc [ OH_SOLAR ]
;”OH_SOLAR” IN [MJ/M2]
;OUTPUT EVERY SIXTY MINUTES:
;AVERAGE ONE-HOUR-AIR-TEMP, AVERAGE ONE-HOUR-VAPOR-PRESSURE-DEFICIT
;CUMMULATIVE ONE-HOUR-SOLAR-RADIATION, AVERAGE ONE-HOUR-VAPOR-PRESSURE
54: Wind Vector (P69)
1: 1 Reps
2: 0000 Samples per Sub-Interval
3: 0 S, é1, & å(é1) Polar
4: 4 Wind Speed/East Loc [ WIND_SPD ]
5: 5 Wind Direction/North Loc [ WIND_DIR ]
55: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 30 Then Do
56: Z=F (P30)
1: 0.0 F
2: 00 Exponent of 10
3: 12 Z Loc [ OH_SOLAR ]
57: End (P95)
;AFTER THE OUTPUT PROCESS, SET CUMMULATIVE “OH_SOLAR” TO ZERO
;=============== END OF HOURLY OUTPUT =======================