TDR100
40
5: TDR100 Measurement (P119)
1: 00 SDM Address
2: 0 La/L
3: 3006 MMMP Mux & Probe Selection
4: 4 Waveform Averaging
5: 1 Vp
6: 250 Points
7: 5.75 Cable Length (meters)
8: 5 Window Length (meters)
9: .3 Probe Length (meters)
10: .085 Probe Offset (meters)
11: 11 Loc [ WC_3001 ]
12: 1138 Mult
13: -0.1758 Offset
;Switch the level 1 SDMX50 to Channel 1 and measure the 8 probes on the Level 2
;multiplexer that is connected to channel 1 of the level 1 mux (apparent cable length to
;probe 9.5 meters):
6: TDR100 Measurement (P119)
1: 00 SDM Address
2: 0 La/L
3: 1108 MMMP Mux & Probe Selection
4: 4 Waveform Averaging
5: 1 Vp
6: 250 Points
7: 9.5 Cable Length (meters)
8: 5 Window Length (meters)
9: .3 Probe Length (meters)
10: .085 Probe Offset (meters)
11: 17 Loc [ WC_1101 ]
12: 1138 Mult
13: -0.1758 Offset
;Switch the level 1 SDMX50 to Channel 2 and measure the 7 probes
;(channels 1 through 7) on the Level 2 multiplexer that is connected to channel 2
;of the level 1 mux (apparent cable length to probe 10 meters):
7: TDR100 Measurement (P119)
1: 00 SDM Address
2: 0 La/L
3: 2107 MMMP Mux & Probe Selection
4: 4 Waveform Averaging
5: 1 Vp
6: 250 Points
7: 9.5 Cable Length (meters)
8: 5 Window Length (meters)
9: .3 Probe Length (meters)
10: .085 Probe Offset (meters)
11: 25 Loc [ WC_2101 ]
12: 1138 Mult
13: -0.1758 Offset