Section 6. Data Error Detection
6-5
4: Do (P86)
1: 11 Set Flag 1 High
;end of filter setup
5: End (P95)
;poll SDM-SIO4 to see if data is available for the datalogger to collect
;the value from the poll is read into location 1
6: SDM-SIO4 (P113)
1: 1 Reps
2: 0 Address
3: 1 Send/Receive Port 1
4: 1 Command
5: 0 1st Parameters
6: 0 2nd Parameters
7: 1 Values per Rep
8: 1 Loc [ _________ ]
9: 1 Mult
10: 0 Offset
;if the value in location 1 is greater than zero then there must be data
;this assumes only one sensor is connected to the SDM-SIO4
7: IF (X<=>F) (P89)
1: 1 X Loc [ _________ ]
2: 3 >=
3: 1 F
4: 30 Then Do
;if data is available then get the value and put into location 2
8: SDM-SIO4 (P113)
1: 1 Reps
2: 0 Address
3: 1 Send/Receive Port 1
4: 4 Command
5: 0 1st Parameters
6: 0 2nd Parameters
7: 1 Values per Rep
8: 2 Loc [ _________ ]
9: 1 Mult
10: 0 Offset
;end of get data.
8: End (P95)
*Table 2 Program
02: 0.0000 Execution Interval (seconds)