Appendix F. CR510PB w/ P193 Master to CR205s Network
F-5
7: PakBus - Wireless Network Master (P193)
1: 5 Number of Remotes
2: 1 First Remote Address ; 1st CR205 "Datalogger Address"
3: 0 Time Into Transmit Interval (sec)
4: 0 Transmit Interval (sec, 0 = use execution interval) ;
Must = P193 execution interval
5: 0 Transmit Delay Between Remotes (sec)
6: 3 Swath to Receive ; Values/remote
7: 4 First Loc for Data Received [ Remote1_1 ]
8: 3 Swath to Send
9: 1 First Loc to Send [ Battery ]
10: 21 Result Code Loc [ ResultCode1 ]
*Table 2 Program
02: 0.0000 Execution Interval (seconds)
*Table 3 Subroutines
End Program
Input Locations can be designed something like this:
FIGURE F-1. P193 Input Locations Editor
To each CR205, connect a 109-L thermister temperature probe to SE1,
, and EX1.
Or, you can simulate the 109-L using a 22K resistor and a 10K resistor
(1% or 5% tolerance, 1/8 watt to 1/2 Watt). Connect the 22K resistor