07QUICK START USER MANUAL ENVOY
GREENSPAN
2.5 Available Connections
Input/Output connectors:
SLR+SLR–:
The Envoy has a built-in charging regulator for charging a 12 V lead-acid battery from an external power source.
Charging power can come from a 16–22 V DC input such as a solar panel.
PWR+ PWR–:
The Envoy is powered by a nominal 12 V DC source. Acceptable power range is 7 to 16 V DC.
C1 C2:
Digital I/O – configurable for SDI-12 communication, state, frequency, and pulses.
PLLEX PSW:
Configurable for counts or frequency of the following signal types:
• High-level square waves (PSW)
• Switch closures (PSW)
• Low-level A/C sine waves (PLLEX).
G:
Ground
SW12:
Switched 12 volts (SW12 V): (switch on/off) primary voltage under program control for control of external devices
requiring 12 V DC, such as humidity sensors. SW12 V can source up to 900 mA.
AG:
Analogue ground
SE1 SE2:
Analogue channels configurable for input/output.
The connectors are all labelled, and there is also a guide to the connectors on the ENVOY body.