Raven EDGE/GPRS for Cingular - User Guide, version 2.31 75
AT Commands: UDP
*UDPLAST=n
*USD=n
If enabled, sets S53 to the last accepted
IP address through UDP auto answer. This can be used
in conjunction with MD3 so that when there is no UDP session, new ethernet host data will
cause a connection to be restored to the last IP accepted through UDP auto answer. .
n=0 : Does not change S53 setting. (Default).
n=1 : Set S53 to the last ac
cepted IP.
Note: This does not change the S53 setting in NVRAM. If the modem is reset, the
original S53 setting will be restored from NVRAM.
Waits the specified delay before sending the first UDP packet
and the
subsequent UDP packets
out to the serial port.
n=1 - 255 Delay in 100ms units, from 100 ms to 25.5 sec.
n=0 : No UDP pa
cket delay (Default).