Figure 5: Diagram describing siting process. A. Initial location is at least 4H units away from the tallest obstacle in
the clearing of height H. B. The next obstacle of height T should be at least 4T units away from the station; it is not
(within the second dashed circle). Therefore the station needs to be moved west. C. New location of the station is
now at least 4T units away from obstacle of height T (and still 4H units away from obstacle of height H). D. Now
the potential location is within 4C units away from house of height C and needs to be moved north. E. New location
is suitable and complies with distance requirements from all obstacles.
Siting the Radiation Sensor
There are two possibilities for locating the radiation sensor based on the local conditions and
structures present at the site: