Figure 13: Cabling diagram showing 1) how to connect the cables coming from the American Vaisala sensors to the
cabling box inside the aspirated radiation shield; ground cables can be combined into one slot (e.g. black & white
into slot 3) and 2) cabling the whole system into the CR 1000 data logger.
Figure 14: Cabling diagram showing 1) how to connect the cables coming from the European Vaisala sensors to the
cabling box inside the aspirated radiation shield; ground cables can be combined into one slot (e.g. black & white
into slot 3) and 2) cabling the whole system into the CR1000 data logger.
3. Replace the top cover of the cabling box. Once the sensors are connected to the cabling
box replace the top of the box ensuring the sensor terminal cables feed out of the
rubberized wedge located on one side of the cabling box cover. Make sure that the
sensor terminal cables are not tensed inside the box and tighten the screws of the
cover to secure it firmly. If the sensor cables are too tense within the cabling box they
may come loose.