CR800 and CR850 Overview
Click on the Wiring Diagram tab to view the sensor wiring diagram, as shown
below. Wire the Type T Thermocouple (provided) to the CR800 as shown on
the diagram. Click the Sensors tab and the Home button to return to the Home
page to continue with Step 3.
Step 3: Output Processing
Step 3 is to define the output processing for the sensor measurements. From
the Home page, click the Output button.
The Output screen has a list of Selected Sensors on the left, and Output Tables
on the right. The default is for two Tables, Table1 and Table2. Both Tables
have a Store Every field and the drop-down list box that are used to set the
interval at which data will be stored.
The objective for this exercise calls for a one-minute output processing. To
remove Table2, Click on the Table2 tab to activate it, and click the Delete
Table button.
The Table Name field is the name that will be used for the Table in which the
output will be stored. Change the default Name of Table1 to OneMin, and
change the interval to 1 minute.
The Selected Sensors list is provided on the left side of the screen. To add a
sensor measurement to the Output Table, highlight a measurement and click
one of the output buttons; e.g., Average. Select the Default, Panel Temp, and
Type T TC sensors and click the Average button to add them to the OneMin
Table.
OV-25