SECTION
7. MEASUREMENT
PROGRAMMING
EXAMPLES
7.7
ANEMOMETER
WITH
PHOTOCHOPPER
OUTPUT
An anemometer with
a
photochopper
transducer
produces
a
pulsed
output which
is monitored
with
the Pulse
Count Instruction,
configured for
High Frequency
Pulses. The
anemometer
used
in
this example is the
R.M. Young
Model No.
12102D
Cup Anemometer which
has
a 10
window
chopper
wheel.
The
photochopper
circuitry is
powered
from
the 21X
or 21XL
12V
supply.
Supplemental charging,
AC
or solar,
should
be used
with
the 21XL.
lf a
charging
source is not
practical,
back-up
batteries
should
be used
to compensate for the increased
current
drain.
Wind
speed is desired
in
meters
per
second.
There
is
a
pulse
each time a window
in
the
chopper
wheel,
which
revolves
with the
cups,
allows light
to
pass
from
the source
to
the
photoreceptor.
Because there are 10
windows
, A
in the
chopper wheel, there are t0
pulses per
I
'6
revolution.
Thus, 1 rpm is
equalto 10
pulses
per
60 seconds
(1
minute)
or 6 rpm
=
1
pulse
per
second. The manufacturer's
calibration for
relating
wind speed to rpm is:
Wind speed
(m/s)
=
0.01632
m/s/rpm
x rpm
+ 0.2 m/s
Pulse
count instruction has the
option of
converting
counts
to frequency
in Hz
(counts/second).
The multiplier
and
offset to
conveft Hz
to meters
per
second
are:
m/s
=
0.01632
m/s/rpm
x
6
rpm/Hz
x XHz
+ 0.2 m/s
=
0.0979 mls/Hz x XHz +
0.2 m/s
There
are times when the 21X is not
able to
reset
the
pulse
counters at the exact
time
interval
programmed.
lf
the artificially large wind
speed
that results from a long interual
is
used,
it
causes a false
average or
maximum
value. To
avoid this,
the 21X
is instructed
to discard
values
resulting
from
long intervals
and use
the
previous
value instead.
7-4
ANEMOMETER
SUPPLY
GROUND
AND SIGNAT REFERE
PULSE
OUI
01: P3
01: 1
02: 1
r03:
20
04: 10
05:
06:
FIGURE
7.7-1.
Wiring Diagram for
Anemometer
PROGRAM
Pulse
Rep
Pulse Input
Chan
High frequency;
Output
Hz.
Loc
[:WS
m/s
1
.0979 Mult
.2 Otfset
TIPPING
BUCKET
RAIN
GAUGE
WITH
LONG
LEADS
A tipping bucket
rain
gauge
is measured
with
the Pulse
Count
Instruction
configured for
Closure.
Counts
from
long intervals will be
(an
option in Parameter 3),
as
the
final
output
desired is
total
rainfall
(obtained
with lnstruction
T2,Totalize).
lf
counts from long intervals
were
discarded,
less
rainfallwould
be
recorded than
was actually measured by the
gauge
(assuming
there were
counts
in
the long intervals).
Output
is desired in millimeters of
precipitation.
The
gauge
is
calibrated
for a 0.01 inch tip;
a
multiplier
of 0.254
is used.
CONNECTIONS
3OO, LEAD
LENGTH
FIGURE 7.8-1.
Wiring
Diagram for Rain
Gauge
with
Long Leads
In a long
cable
there is appreciable
capacitance
between the lines,
which is
discharged across
the
switch when
it closes. In
addition to