SECTION
9. INPUT/OUTPUT
INSTRUCTIONS
PARAM.
DATA
NUMBER TYPE
DESCRIPTION
Repetitions
Range
code
Input
channel number for
first measurement
Excitation
channel
number
Excitation
voltage
(millivolts)
Input
location number
for
first measurement
Multiplier
Offset
Input
locations altered: 1
per
measurement
***
6 FULL BRIDGE
***
FUNCTION
This
instruction is
used to apply
an excitation
voltage
to a
full
bridge
(Figure
13.5-1), make
a
differential voltage
measurement
of
the
bridge
output,
reverse the
excitation
voltage,
then
repeat
the
measurement. The
result is 1000
times
the
ratio
of the
measurement
to
the
excitation
voltage.
A
1
before
the excitation
channel
number
(1X)
causes the channel to be
incremented with
each
repetition.
PARAM. DATA
NUMBER
TYPE
DESCRIPTION
Repetitions
Range
code
Input channel number for
first measurement
Excitation
channel
number
Excitation
voltage
(millivolts)
Input location number
for
first measurement
Multiplier
Offset
Input
locations
altered:
1
per
measurement
***
7
THREE
WIRE HALF
BRIDGE
***
FUNCTION
This
instruction is
used to determine
the
ratio
of
the
sensor
resistance
to
a known
resistance
using
a separate voltage
sensing wire from
the
sensor
to
compensate
tor
lead
wire
resistance.
9-4
The measurement
sequence is
to
apply
an
excitation
voltage,
make two voltage
measurements
on
two
adjacent
single-ended
channels,
the first on the reference resistor
and
the
second on the voltage
sensing
wire
from
sensor
(Figure
13.5-1),
then reverse the
excitation voltage
and
repeat
the
measurements. The two measurements
are
used
to
calculate
the
resulting
value, which is
the ratio of the voltage across
the
sensor
to the
voltage
across the reference resistor. A 1
before
the
excitation channel number
(1X)
causes the channelto be incremented with
repetition.
PARAM.
DATA
NUMBER TYPE DESCRIPTION
2 Repetitions
2 Range
code
for
both
measurements
Input
channel number for
first measurement
2 Excitation
channel
4 Excitation
voltage
(millivolts)
Input location number
for
first measurement
FP Multiplier
FP
Otfset
Input locations altered: 1
per
measurement
***
8
DIFFERENTIAL VOLTAGE WITH
***
EXCITATION
AND DELAY
FUNCTION
This measurement
consists of applying
a
single
excitation voltage,
delaying a specified time,
making a differential voltage
measurement. lf a
0
delay
is specified, the inputs
are
not
switched
for
a second integration as is normally the
case
with
a differential measurement
(Section
13.2).
The
result stored is the
voltage
measured. W
a delay
of
0 lnstruction 8 does not have as
resolution
or common mode rejection as
the
ratiometric
bridge measurement instructions. lt
does
provide
a very rapid means
of
making
bridge measurements
as
well
as supplying
excitation to
ci
rcu itry requ i ri
n
g
d iff erential
measurements. This instruction
does
not
reverse excitation.
01:
02:
03:
o4:
05:
06:
07:
08:
05:
06:
FP
FP
07:
08: