Table 1 Programs
Sec. Execution
lnterval
Pulse
Rep
Pulse
Input Chan
Switch
closure
Loc
[:Rain
(mm)]
Mult
Offset
lf time
is
minutes
into a
minute interval
Set
high
Flag 0
(output)
Set
Active Storage
Area
Input
Storage
Area
Array
lD or
location
Totalize
Rep
Loc
Rain
(mm)
lf
X<=>F
X Loc
1Smin tot
F
Then Do
Set
Active
Storage Area
Final Storage
Area
Array
lD or location
RealTime
Day,Hour-Minute
Sample
Rep
Loc
1smin
tot
End
End
Table
1
SECTION 8.
PROCESSING AND
PROGRAM CONTROL
EXAMPLES
1:Rain
(mm)
2:1Smin tot
*1
01: 60
01:
01:
o2'.
03:
o4:
05:
06:
02:
P92
01: 0
02:
15
03: 10
P3
1
1
2
1
es4
0l
8.3 USING CONTROL
PORTS AND
LOOP TO RUN
AM416
MULTIPLEXER
This example uses an
AM416 to measure
16
copper-constantan
thermocouples
and
16 Model
223 soil moisture blocks.
The sensors are
read
every
ten
minutes and
the average
value output
once
an
hour. The
multiplexer
is housed in an
AM-ENCT enclosure
to minimize thermocouple
errors created
by thermal
gradients.
Thermocouple Wire
is run from the 21X to
the
AM416
common
used
for the
TC
measurements
and the 21X
panel
temperature
is
used
for the
reference
temperatu
re.
The AM416 switches
lhe 223
moisture
block
out
of the
circuit
when
it is not
being measured.
This eliminates the
need for the
blocking
capacitors used
in the
model
227
soil moisture
block. The
223 blocks are
about
one
fifth the
cost of lhe 227 blocks.
Control
ports
are used
to
reset the
AM416
and
clock it through
its channels.
The
sequence
of
the
program
is:
Measure
the 21X
panel
temperature
for TC temperature
reference.
21X
sets the
port
high which resets the
AM416.
A loop
is entered;
within each
pass:
The
port
clocking
the
AM416
is
pulsed.
The connected
TCs and moisture
blocks
are
measured.
21X sets
the
port
controlling
AM416
reset
low.
Soil
moisture
measurements are
converted
to block
resistances.
The input location
in which the temperature
and
soil moisture
measurements
are stored
is
indexed
to the
loop counter
(lnstruction
87,
Section 12). An
indexed
location is incremented
by one with each
pass
through the
loop.
For
example, on
the first
pass
temperature
is stored
in Location 2, and
soil moisture in
Location
18.
On
the
second
pass
temperature is stored
in
Location
3,
and soil
moisture
in
Location
18.
After 16 loop
passes,
temperature
and
soil
moisture measurements
occupy
Locations
2
through
17
and
18 through
33, respectively.
Connections are shown
in Figure
8.3-1.
03:
01:
02:
04:
01:
02:
05:
01:
02:
03:
o4:
06:
01:
02:
07:
01:
09:
10:
8-3